Fast data acquisition and superb reliability make the Thermo Scientific Evolution Array spectrophotometer the cornerstone of your complete analytical environment.
Instant full-spectrum analysis, room light immunity, and a completeline of accessories deliver simplicity and capability that is second to none.
Full Spectrum Data Acquisition
Photodiode array technology allows you to acquire ful lspectrum UV-Visible data almost instantaneously. Increase efficiency and throughput in:
- Quality Control and Assurance measurements
- Pharmaceutical method development and deployment
- Multi-wavelength kinetics experiments with millisecondresolution
- Routine to research life science applications
- Coating and color applications
- Multi-user analytical and educational laboratories
Clear and Accurate Results
Instant, reliable measurements at an unlimited number of wavelengths accelerates any analysis. Ideal for routine and high-throughput applications in any laboratory, the Evolution Array offers:
- Wavelength monitoring with automated or manual peakpicking options for up to 20 peaks or valleys
- Customized single and multi-component quantitativemethods with the entry of up to 100 standards
- Convenient pre-defined biological methods for proteins andnucleic acids
- Acquisition of a full spectrum every 20 milliseconds with UltraKinetics
- Materials analysis software for film thickness and coloranalysis
Accessories For Every Application
A complete line of accessories allows you to customize your Evolution Array for the unique demands of your laboratory. Get more accuracy and productivity from your spectrophotometer:
- An Automated Referencing Stage eliminates drift from longterm experiments
- Temperature Control accessories provide accurate and reliable results for kinetics and thermal denaturation assays
- Transmittance and Reflectance accessories bring
-
Specification |
Wavelength Accuracy |
±0.2nm (Deuterium Lamp) / ±0.5nm (Holmium Oxide) |
Wavelength Range |
190 - 1100nm |
Photometric Accuracy |
±0.005 A (440 and 590nm, Neutral Density Filter) / ±0.01 A (K2Cr2O7, 60mg/L) |
Photometric Range |
±4 A |
Photometric Linearity |
~3 A |
Repeatability |
<0.001 A (440 and 590nm, Neutral Density Filter) / <0.002 A (K2Cr2O7, 60mg/L) |
Wavelength Typical Scan Speed |
<1s (190 - 1100nm) |
Wavelength Fastest Scan Speed |
0.02 s (190 - 1100nm) |
Photometric Linear Range |
~3 A |
Baseline Flatness |
< 0.0005 A |
Scan Ordinate Modes |
Abs, %T, %R, Intensity |
Drift |
<0.001 A/hr at 0A, 300nm / <0.0005 A/hr with ARS |
Light Source |
Pre-aligned Deuterium, Pre-aligned Tungsten (~10,000 hr lifetime) |
Resolution |
> 1.6 (Toluene in Hexane) |
Scan Speed |
< 0.02 nm (ten consecutive scans), RMS |
Detector |
1024-element Photodiode Array |
Cat. No. |
Description |
10148888 |
Evolution Array Uv-Vis Spectrophotometer |
|